Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Electrochemical behavior and voltammetric determination of pyrazinamide using a poly-histidine modified electrode

Texto completo
Autor(es):
Bergamini, Marcio F. [1] ; Santos, Daniela P. [2] ; Zanoni, Maria Valnice B. [2]
Número total de Autores: 3
Afiliação do(s) autor(es):
[1] UFPR, Ctr Politecn, Dept Quim, Lab Sensores Eletroquim LabSensE, BR-81531990 Curitiba, PR - Brazil
[2] UNESP Sao Paulo State Univ, Dept Analyt Chem, Inst Chem Araraquara, BR-14801970 Araraquara, SP - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF ELECTROANALYTICAL CHEMISTRY; v. 690, p. 47-52, FEB 1 2013.
Citações Web of Science: 28
Resumo

Pyrazinamide (Pyrazinecarboxamide - PZA) is a drug that is used to treatment tuberculosis. In the present work, the voltammetric behavior of PZA was studied using a screen-printed modified electrode (SPCE). The modified electrode was constructed using poly-histidine films, and it showed an electrocatalytic effect, thus promoting a decrease in PZA reduction potential and improving the voltammetric response. Cyclic voltammetry and electrochemical impedance spectroscopy techniques have been employed in order to elucidate of the electrodic reaction. The results allowed the proposal that in the PZA reduction, a further chemical reaction occurs that corresponds to a second-order process which is subsequent to the electrode reaction. In addition, a sensitive voltammetric method was developed, and it was successfully applied for PZA determination in human urine samples. The best response was found using SPCE modified with poly-histidine prepared by histidine monomer electropolymerization (SPCE/EPH). The electroanalytical performance of the SPCE/EPH was investigated by linear sweep (LSV), differential pulse (DPV), and square wave voltammetry (SWV). A linear relationship between peak current and PZA concentrations was obtained from 9.0 x 10(-7) to 1.0 x 10(-4) mol L-1 by using DPV. The limit of detection at 5.7 x 10(-7) mol L-1 was estimated, and a relative standard deviation of the 5.0 x 10(-6) mol L-1 of PZA of 10 measurement was 3.7%. (C) 2012 Elsevier B.V. All rights reserved. (AU)

Processo FAPESP: 04/00111-8 - Desenvolvimento e aplicação de sensores eletroquímicos baseados em filmes poliméricos de poli-L-histidina
Beneficiário:Marcio Fernando Bergamini
Linha de fomento: Bolsas no Brasil - Doutorado
Processo FAPESP: 03/06598-3 - Desenvolvimento de eletrodos modificados com poli acido glutamico e sua aplicacao na analise de compostos antioxidantes e farmaceuticos.
Beneficiário:Daniela Pereira dos Santos
Linha de fomento: Bolsas no Brasil - Doutorado