Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Oxacillin Resistance and Antimicrobial Susceptibility Profile of Staphylococcus saprophyticus and Other Staphylococci Isolated from Patients with Urinary Tract Infection

Texto completo
Autor(es):
Ferreira, Adriano M. [1, 2] ; Bonesso, Mariana F. [1, 2] ; Mondelli, Alessandro L. [3] ; Camargo, Carlos H. [3] ; Cunha, Maria de Lourdes R. S. [1, 2]
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] UNESP Univ Estadual Paulista, Botucatu Biosci Inst, Dept Microbiol & Imunol, BR-18618970 Botucatu, SP - Brazil
[2] UNESP Univ Estadual Paulista, Botucatu Sch Med, Dept Trop Med, BR-18618970 Botucatu, SP - Brazil
[3] UNESP Univ Estadual Paulista, Botucatu Sch Med, Dept Internal Med, BR-18618970 Botucatu, SP - Brazil
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: Chemotherapy; v. 58, n. 6, p. 482-491, 2012.
Citações Web of Science: 9
Resumo

Background: Staphylococcus saprophyticus is the second most frequent community-acquired causative agent of urinary tract infection (UTI). The objective of this study was to evaluate the susceptibility profile and resistance detection in Staphylococcus species. isolated from patients with UTI. Materials and Methods: The isolates were investigated using the disk diffusion method, Vitek I system, E-test (R), and detection of the mecA gene. Results: Most isolates (76.2%) were resistant to oxacillin by the disk diffusion method, followed by those resistant to penicillin (72.2%). The oxacillin disk diffusion method, E-test, and Vitek I method showed higher sensitivity (94.4%) and lower specificity (28.9, 26.5, and 24.0%, respectively) than the cefoxitin disk diffusion test (sensitivity: 83.5%, specificity: 85.5%) for the detection of oxacillin resistance. Conclusions: The large number of oxacillin-resistant isolates indicates that the breakpoint value recommended by the Clinical and Laboratory Standards Institute may overestimate oxacillin resistance in S. saprophyticus. Thus, changes in these guidelines are necessary for the correct detection of this resistance. Copyright (C) 2013 S. Karger AG, Basel (AU)

Processo FAPESP: 09/10083-5 - Comparação de métodos de identificação e perfil de sensibilidade aos antimicrobianos em Staphylococcus spp. isolados de pacientes com infecção do trato urinário (ITU)
Beneficiário:Maria de Lourdes Ribeiro de Souza da Cunha
Modalidade de apoio: Auxílio à Pesquisa - Regular
Processo FAPESP: 12/25108-6 - Oxacillin resistance and antimicrobial susceptibility profile of Staphylococcus saprophyticus and other Staphylococci isolated from patients with urinary tract infection
Beneficiário:Maria de Lourdes Ribeiro de Souza da Cunha
Modalidade de apoio: Auxílio à Pesquisa - Publicações científicas - Artigo