Reliability of isokinetic evaluation in passive mo... - BV FAPESP
Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Reliability of isokinetic evaluation in passive mode for knee flexors and extensors in healthy children

Texto completo
Autor(es):
Santos, Adriana N. [1] ; Pavao, Silvia L. [1] ; Avila, Mariana A. [2] ; Salvini, Tania F. [2] ; Rocha, Nelci A. C. F. [1]
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] Univ Fed Sao Carlos UFSCar, Phys Therapy Dept, Neuropediat Sect, Sao Carlos, SP - Brazil
[2] Univ Fed Sao Carlos UFSCar, Phys Therapy Dept, Neuromuscular Plast Sect, Sao Carlos, SP - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: BRAZILIAN JOURNAL OF PHYSICAL THERAPY; v. 17, n. 2, p. 112-120, MAR-APR 2013.
Citações Web of Science: 9
Resumo

Background: The isokinetic dynamometer has been considered the gold-standard measurement of muscle performance. However, the reliability for the passive mode in children has not been reported to date. Objectives: The purpose was to evaluate the reliability of the isokinetic dynamometer in passive mode in children. Method: Twenty-one healthy children (ten girls, eleven boys), aged 5 to 12 years (age: 8.5 +/- 2.2 years), were evaluated using an isokinetic dynamometer. Each participant was tested twice with a one-week interval and performed five consecutive cycles of knee extension and flexion. The test was performed at 60 degrees/s in the concentric passive mode and the children performed maximal contractions. The measured variables were peak torque, average peak torque, total work, and average power, time to peak torque and angle of peak torque for dominant and non-dominant lower limbs. Reliabilities were determined using intraclass correlation coefficient (ICC3,1), standard error of measurement (SEM and SEM%), and coefficient of variation (CV). Results: We found good reliability in both lower limbs for peak torque, average peak torque, total work and average power of knee flexors and extensors, with ICC3,1 values greater than 0.80; SEM ranging from 6.7 to 79.2; SEM% ranging from 10.4% to 16.8%; CV lower than 15%. Bland-Altman analysis showed that the bias was low than 10% and limits of agreement (LOAs) ranging from 33.9% to 59.2%, and -28.8% and -52.8%, showing that measures tended to disagree. However, time to peak torque (ICC3,1<0.68; SEM > 0.34; SEM%> 37.4%; CV> 41.7%; bias > 24.0%; LOA>101.0%) and angle of peak torque(ICC3,1<0.76; SEM>9.3; SEM%>27.6%; CV>15.3%; bias>11.0%; LOA>61.0%) were not reliable. Conclusions: The findings indicate that isokinetic evaluation in passive mode for knee extensors and flexors of dominant and non-dominant lower limbs of children without disabilities was reliable for peak torque, average peak torque, work, and power. However, average time to peak torque and angle of peak torque were not reliable. (AU)

Processo FAPESP: 10/12688-9 - Atividade sentado para de pé em crianças com paralisia cerebral: relação com a força muscular e a participação social
Beneficiário:Adriana Neves dos Santos
Modalidade de apoio: Bolsas no Brasil - Mestrado