Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Influence of powder-to-water ratio on radiopacity, setting time, pH, calcium ion release and a micro-CT volumetric solubility of white mineral trioxide aggregate

Texto completo
Autor(es):
Cavenago, B. C. [1] ; Pereira, T. C. [1] ; Duarte, M. A. H. [1] ; Ordinola-Zapata, R. [1] ; Marciano, M. A. [1] ; Bramante, C. M. [1] ; Bernardineli, N. [1]
Número total de Autores: 7
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Bauru Sch Dent, Dept Operat Dent Endodont & Dent Mat, Sao Paulo - Brazil
Número total de Afiliações: 1
Tipo de documento: Artigo Científico
Fonte: International Endodontic Journal; v. 47, n. 2, p. 120-126, FEB 2014.
Citações Web of Science: 30
Resumo

AimTo evaluate the radiopacity, setting time, pH level, calcium ion release and solubility of white mineral trioxide aggregate (MTA; Angelus, Londrina, Pr, Brazil) with different powder-to-water ratios. MethodologyThree MTA groups were prepared using 4:1, 3:1 and 2:1 powder-to-water ratios. For the radiopacity analysis, the 10x1mm specimens were arranged on occlusal films with a cylinder of dentine and an aluminium stepwedge. The digitized radiographs were evaluated with Digora 1.51 software to determine the radiographic density. The setting time test was performed according to the American Society for Testing and Materials 266/08 standard specifications, but the specimens were made according to International Organization for Standardization 6876:2001. Thirty acrylic teeth with root-end filling material were immersed in ultrapure water for measurement of pH level and calcium ion release (atomic absorption spectrophotometer) at 3, 24, 72 and 168h. In the solubility test, the root-end fillings of 30 acrylic teeth were scanned twice by a Micro-CT, before and after immersion in ultrapure water for 168h. Digital data were reconstructed, and the volume (mm(3)) of the samples was obtained using CTan software (CTan v1.11.10.0, SkyScan). The data were statistically analysed by the anova, Tukey, Kruskal-Wallis and Dunn's tests. ResultsThe radiopacity was higher (P<0.05) when the 4:1 proportion was utilized. The setting time was longer, and the pH level and calcium ion release were higher (P<0.05) with a greater volume of water. The group with more water (2:1) had significantly (P<0.05) more material volume loss (6.46%) compared with the other groups. ConclusionsThe ratio of powder/water significantly interfered with the physical and chemical properties of white MTA Angelus. (AU)

Processo FAPESP: 11/18272-1 - O efeito do uso de fitoterápicos e da própolis nas propriedades físico-químicas, antimicrobiana e biocompatibilidade do MTA
Beneficiário:Bruno Cavalini Cavenago
Modalidade de apoio: Bolsas no Brasil - Doutorado
Processo FAPESP: 10/16072-2 - Microtomógrafo (MicroTC) no estudo da anatomia dental e nos procedimentos endodônticos
Beneficiário:Clovis Monteiro Bramante
Modalidade de apoio: Auxílio à Pesquisa - Regular