Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Velar activity in individuals with velopharyngeal insufficiency assessed by acoustic rhinometry

Texto completo
Autor(es):
Kiemle Trindade, Inge Elly [1, 2] ; Adorno Marmontel Araujo, Bruna Mara [2] ; Martins Sampaio Teixeira, Ana Claudia [2] ; Carneiro da Silva, Andressa Sharllene [2] ; Trindade-Suedam, Ivy Kiemle [1, 2]
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Bauru Sch Dent, Dept Biol Sci, BR-17012900 Bauru, SP - Brazil
[2] Univ Sao Paulo, Hosp Rehabil Craniofacial Anomalies, Physiol Lab, BR-17012900 Bauru, SP - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: Journal of Applied Oral Science; v. 22, n. 4, p. 323-330, JUL-AUG 2014.
Citações Web of Science: 3
Resumo

Acoustic rhinometry is routinely used for the evaluation of nasal patency. Objective: To investigate whether the technique is able to identify the impairment of velopharyngeal (VP) activity in individuals with clinical diagnosis of velopharyngeal insufficiency (VPI). Methods: Twenty subjects with repaired cleft palate and inadequate velopharyngeal function (IVF) and 18 non-cleft controls with adequate velopharyngeal function (AVF), adults, of both genders, were evaluated. Area-distance curves were obtained during VP rest and speech activity, using an Eccovision Acoustic Rhinometry system. Volume was determined by integrating the area under the curve at the segment corresponding to the nasopharynx. VP activity (ΔV) was estimated by the absolute and relative differences between nasopharyngeal volume at rest (Vr) and during an unreleased /k/ production (Vk). The efficiency of the technique to discriminate IVF and AVF was assessed by a ROC curve. Results: Mean Vk and Vr values (±SD) obtained were: 23.2±3.6 cm3 and 15.9±3.8 cm3 (AVF group), and 22.7±7.9 cm3 and 20.7±7.4 cm3 (IVF group), corresponding to a mean ΔV decay of 7.3 cm3 (31%) for the AVF group and a significantly smaller ΔV decay of 2.0 cm3 (9%) for the IVF group (p<0.05). Seventy percent of the IVF individuals showed a ΔV suggesting impaired VP function (below the cutoff score of 3.0 cm3 which maximized both sensitivity and specificity of the test), confirming clinical diagnosis. Conclusion: Acoustic rhinometry was able to identify, with a good discriminatory power, the impairment of VP activity which characterizes VPI. (AU)

Processo FAPESP: 00/04354-1 - Efeitos da correção cirúrgica das deformidades nasais de portadores de fissura lábio-palatina sobre a permeabilidade nasal estimada por rinometria e nasometria
Beneficiário:Inge Elly Kiemle Trindade
Modalidade de apoio: Auxílio à Pesquisa - Regular