Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Selective and sensitive voltammetric determination of folic acid using graphite/restricted access molecularly imprinted poly(methacrylic acid)/SiO2 composite

Texto completo
Autor(es):
Kuceki, Michele [1] ; de Oliveira, Fernanda Midori [1] ; Segatelli, Mariana Gava [1] ; Lombello Coelho, Malena Karla [2] ; Pereira, Arnaldo Cesar [2] ; da Rocha, Luana Rianne [1] ; Mendonca, Jhessica de Cassia [1] ; Teixeira Tarley, Cesar Ricardo [1, 3]
Número total de Autores: 8
Afiliação do(s) autor(es):
[1] Univ Estadual Londrina, Dept Quim, Rodovia Celso Garcia Cid, PR 445, Km 380, BR-86050482 Londrina, PR - Brazil
[2] Univ Fed Sao Joao Rei UFSJ, Dept Ciencias Nat, Campus Dom Bosco, Praca Dom Helvecio 74, BR-36301160 Sao Joao Del Rei, MG - Brazil
[3] Univ Estadual Campinas, UNICAMP, Inst Nacl Ciencia & Tecnol Bioanalit INCTBio, Inst Quim, Dept Quim Analit, Cidade Univ Zeferino Vaz Campus S-N, BR-13083861 Campinas, SP - Brazil
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF ELECTROANALYTICAL CHEMISTRY; v. 818, p. 223-230, JUN 1 2018.
Citações Web of Science: 4
Resumo

The present study demonstrates the development of a voltammetric sensor based on graphite/restricted access molecularly imprinted poly(methacrylic acid)/SiO2 composite for folic acid determination in pharmaceutical formulation. The insertion of hybrid molecularly imprinted polymer with restricted access (RAM-MIP) into the graphite paste provided enhance in the cathodic peak current for FA. As the electric conductivity of RAM-MIP is very poor, the optimum content was found to be very low (3%, w/w) in the composite. Under optimized conditions (0.1 mol L-1 Britton-Robinson buffer and pH 4.5) using square wave voltammetry (frequency of 150 Hz, pulse amplitude of 90 mV and potential increment of 7 mV) a limit of detection of 0.72 mu g L-1 (1.63 nmol L-1) and a linear range from 5.0 to 100.0 mu g L-1 (0.01 to 0.23 mu mol L-1) were obtained. The method precision was assessed in terms of inter-day (n = 6) and infra-day precision (two consecutive days), whose relative standard deviations (RSD%) ranged from 3.56 to 5.01%. The developed method was applied for FA determination in pharmaceutical samples whose accuracy was attested by means of addition and recovery assays (97.7-105.0%) as well as by high performance liquid chromatography (HPLC) as a reference technique, thus indicating that RAM-MIP sensor might be successfully applied for quality control in the real samples. (AU)

Processo FAPESP: 14/50867-3 - INCT 2014: Instituto Nacional de Ciência e Tecnologia de Bioanalítica
Beneficiário:Marco Aurelio Zezzi Arruda
Modalidade de apoio: Auxílio à Pesquisa - Temático