Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Reliable measurement of incisal bite force for understanding the control of masticatory muscles

Texto completo
Autor(es):
Moreira, Luciana S. [1, 2, 3] ; Elias, Leonardo A. [4, 3] ; Germer, Carina M. [3] ; Palomari, Evanisi T. [1, 2]
Número total de Autores: 4
Afiliação do(s) autor(es):
[1] Univ Estadual Campinas, Inst Biol, Cellular & Struct Biol Grad Program, Campinas, SP - Brazil
[2] Univ Estadual Campinas, Inst Biol, Dept Struct & Funct Biol, EMG Motor Control & Expt Electrothermotherapy Lab, Campinas, SP - Brazil
[3] Univ Estadual Campinas, Sch Elect & Comp Engn, Dept Biomed Engn, Neural Engn Res Lab, Campinas, SP - Brazil
[4] Univ Estadual Campinas, Ctr Biomed Engn, Campinas, SP - Brazil
Número total de Afiliações: 4
Tipo de documento: Artigo Científico
Fonte: ARCHIVES OF ORAL BIOLOGY; v. 112, APR 2020.
Citações Web of Science: 0
Resumo

Objective: In the present study, we aimed at evaluating the steadiness of incisal bite force during isometric contractions of masticatory muscles. Design: Two separate experiments were carried out in 11 healthy young women. A first experiment was performed to test the reliability of our protocol for measurement of incisal bite force steadiness. The second experiment aimed to evaluate the steadiness of incisal bite force at four submaximal (i.e., percentage of maximum voluntary contraction, MVC) levels (5 %MVC, 10 %MVC, 15 %MVC, and 20 %MVC), along with the bilateral myoelectric activity of two masticatory muscles (temporalis and masseter). Results: The results from the first experiment showed that our protocol is substantially reliable (intraclass correlation coefficient, ICC > 0.80) for estimating force variability and moderate reliable (0.60 < ICC < 0.80) for estimating spectral properties of force signals. In the second experiment, we found that force standard deviation (SD) increased proportionally to the power of mean force, and coefficient of variation (CoV) was higher at low-intensity contractions and maintained at an approximately constant level for high-intensity contractions. The force-EMG relationships were linear for both muscles at the contraction intensities evaluated in the study (5 % MVC to 20 %MVC), and the median frequency did not change with contraction intensity. Conclusion: Therefore, we presented a reliable method to estimate the incisal bite force, along with additional data on force control and myoelectric activity of jaw elevator muscles during isometric steady contractions. (AU)

Processo FAPESP: 06/61750-3 - Efeito da estimulação elétrica neuromuscular na força e área de secção transversal do músculo quadríceps e eletromiografia da porção obliqua dos músculos vasto medial e vasto lateral em indivíduos normais e com disfunção femoropatelar
Beneficiário:Evanisi Teresa Palomari
Modalidade de apoio: Auxílio à Pesquisa - Regular