Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do SciELO, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Surface functionalization of polyvinyl chloride by plasma immersion techniques

Texto completo
Autor(es):
Péricles Lopes SantAna [1] ; José Roberto Ribeiro Bortoleto [2] ; Nilson Cristino da Cruz [3] ; Elidiane Cipriano Rangel [4] ; Steven Frederick Durrant [5] ; Wido Herwig Schreiner [6]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] Universidade Estadual Paulista. Laboratório de Plasmas Tecnológicos - Brasil
[2] Universidade Estadual Paulista. Laboratório de Plasmas Tecnológicos - Brasil
[3] Universidade Estadual Paulista. Laboratório de Plasmas Tecnológicos - Brasil
[4] Universidade Estadual Paulista. Laboratório de Plasmas Tecnológicos - Brasil
[5] Universidade Estadual Paulista. Laboratório de Plasmas Tecnológicos - Brasil
[6] Universidade Federal do Paraná. Departamento de Física - Brasil
Número total de Afiliações: 6
Tipo de documento: Artigo Científico
Fonte: POLIMEROS-CIENCIA E TECNOLOGIA; v. 30, n. 4 2021-04-23.
Resumo

Abstract In this work we discuss the wettability, chemical composition, surface morphology and optical transmittance of polyvinyl chloride (PVC) samples treated by Plasma Immersion and by Plasma Immersion Ion Implantation. The total pressure of N2 or SF6 was 6.66 Pa, for treatments of 900 s, applied rf power of 25 and 100 W, and the substrate temperature was about 298 K. In PIII, high voltage pulses of -2400 V at a cycle time of 30 µs and a frequency of 300 Hz were used. The wettability of the samples was assessed via contact angle measurements, which indicated either hydrophilicity or hydrophobicity, depending on the plasma composition. X-ray Photoelectron Spectroscopic analysis confirmed strong fluorine attachment to the surface after treatments using SF6 plasmas, and the presence of oxygen after treatments using nitrogen plasmas. Atomic Force Microscopy images showed that the roughness Rrms, depends on the plasma conditions. Optical transmittance in the visible region, T (λ), was increased by plasma immersion. The greatest contact angle observed was 142º (PI cathode), while the highest roughness was 213.2 nm. The highest optical transmittance in the visible region was around to 90% (PI anode). (AU)

Processo FAPESP: 17/15853-0 - Caracterização de Filmes Finos Complexos Obtidos por PECVD e a Deposição de Filmes Finos em Substratos Porosos
Beneficiário:Steven Frederick Durrant
Modalidade de apoio: Auxílio à Pesquisa - Regular