Busca avançada
Ano de início
Entree


Weighing analytical performance and sustainability: a comparative study of manual and automated microextraction by packed sorbent for food contaminant evaluation

Texto completo
Autor(es):
Martins, Rafael O. ; Medina, Deyber Arley Vargas ; Lancas, Fernando M.
Número total de Autores: 3
Tipo de documento: Artigo Científico
Fonte: ANALYTICAL AND BIOANALYTICAL CHEMISTRY; v. 417, n. 17, p. 11-pg., 2025-06-04.
Resumo

Microextraction by packed sorbent (MEPS) has shown promising analytical performance in evaluating contaminants within food samples. Despite significant advancements in transitioning from manual to automated MEPS systems, the literature lacks comprehensive evaluations of the environmental impacts relative to the analytical performance of these approaches. Therefore, this study compares the analytical performance and environmental impact of manual and automated MEPS protocols for evaluating pesticides and antibiotics in food matrices. Results showed excellent linearity for all analytes in both approaches (R-2 > 0.9900), with low limits of detection (LOD) and quantification (LOQ) ranging from 0.020 to 0.045 mu g L--(1) and 0.045 to 1.0 mu g L--(1) for pesticides, respectively, and from 5 to 15 mu g L--(1) and 15 to 20 mu g L--(1) for antibiotics in the manual approach. The automated approach yielded LOD and LOQ values between 0.010 and 0.25 mu g pesticides and 0.5 and 10 mu g L--(1) for antibiotics. Trueness values were between 82 and 109% for the manual method and 91% for the automated process. In the final application, both methods identified and quantified pesticides and antibiotics in corn, tomato, and milk samples. A comprehensive comparison of their analytical performance was conducted, and the environmental impacts of both protocols were evaluated using the AGREEprep analytical tool, which underscored their respective advantages and limitations. This study provides a balanced perspective on the analytical and environmental implications of both manual and automated MEPS approaches, offering readers a comprehensive understanding of each strategy's impact. (AU)

Processo FAPESP: 17/21984-0 - EMU concedido no processo 17/02147-0: sistema de nano-cromatografia líquida de alta eficiência hifenada a espectrometria de massas com ionização por elétrons e analisador quadrupolar (EI-Q (MS)) - nano-LC-EI-MS
Beneficiário:Fernando Mauro Lanças
Modalidade de apoio: Auxílio à Pesquisa - Programa Equipamentos Multiusuários
Processo FAPESP: 17/21985-6 - EMU concedido no processo 17/02147-0: sistema de nano/micro-cromatografia líquida de alta eficiência hifenada a espectrometria de massas com ionização por electrospray e analisador sequencial quadrupolar (ESI-QqQ (MS/MS)) - nano/µ-LC-ESI-MS/MS
Beneficiário:Fernando Mauro Lanças
Modalidade de apoio: Auxílio à Pesquisa - Programa Equipamentos Multiusuários
Processo FAPESP: 23/07159-7 - Síntese, caracterização e emprego de novos sorventes derivados de grafeno em técnicas de separação
Beneficiário:Fernando Mauro Lanças
Modalidade de apoio: Auxílio à Pesquisa - Regular
Processo FAPESP: 23/15675-5 - Preparo, caracterização e aplicações de sorventes híbridos quitosana-óxido de grafeno em microextração por sorvente empacotado (MEPS) automatizado: avaliação de resíduos e contaminantes em matrizes alimentares
Beneficiário:Rafael Oliveira Martins
Modalidade de apoio: Bolsas no Brasil - Pós-Doutorado
Processo FAPESP: 17/02147-0 - Cromatografia líquida em uma gota e seu acoplamento com espectrometria de massas: estratégias instrumentais, desenvolvimento de materiais, automatização e aplicações analíticas
Beneficiário:Fernando Mauro Lanças
Modalidade de apoio: Auxílio à Pesquisa - Temático