Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Determining acceptable limits for water sorption and solubility of interim denture resilient liners

Texto completo
Autor(es):
Maciel, Janaina Gomes [1] ; Campos Sugio, Carolina Yoshi [1] ; Chaves, Giuliana de Campos [1] ; Falcao Procopio, Andrea Lemos [1] ; Urban, Vanessa Migliorini [2] ; Neppelenbroek, Karin Hermana [1]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Dept Prosthodont & Periodont, Bauru Sch Dent, Bauru - Brazil
[2] State Univ Ponta Grossa UEPG, Dept Dent, Ponta Grossa - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF PROSTHETIC DENTISTRY; v. 121, n. 2, p. 311-316, FEB 2019.
Citações Web of Science: 0
Resumo

Statement of problem. Specifications for determining acceptable limits of water sorption (WS) and solubility for interim denture resilient liners are lacking. Purpose. The purpose of this in vitro study was to evaluate the WS and solubility of interim resilient materials throughout their lifespans. Material and methods. Specimens (n=10) of 7 tissue conditioners, Coe-Comfort (CC), Softone (ST), Rite-Line (RL), Dura Conditioner (DC), Hydrocast (HC), Dentusoft (DS), and Visco-gel (VG) and 2 interim resilient liners, Trusoft (TS) and Coe-Soft (CS), were submitted to desorption until weight stabilization. Next, they were immersed in distilled water at 37 degrees C for 3, 5, 7, or 14 days and then weighed, dried, and reweighed. Data (%) were analyzed using 2-way ANOVA and the Tukey honestly significant difference (HSD) test (alpha=.05). Results. VG demonstrated the highest WS (12.06 +/- 0.93%-16.62 +/- 0.87%) and solubility (20.30 +/- 4.26%-23.59 +/- 2.24%; P<.05) percentages. Low WS values were presented by CC (2.23 +/- 0.53%-2.99 +/- 0.49%; P<.05). The WS showed no significant changes for CC, CS, and TS over 14 days (P>.05). SL presented intermediate solubility values (4.09 +/- 1.60%-8.80 +/- 1.15%), and the other materials showed values lower than 3.35 +/- 0.70%. CC, DC, DS, HC, RL, TS, and CS showed no changes in solubility throughout the 14-day trial. Conclusions. Over the lifespan of a tissue conditioner (7 days), CC, RL, DC, HC, DS, CS, and TS presented suitable in vitro performance. Among the tested materials, CC, CS, and TS were considered best suited for denture relining for up to 14 days. (AU)

Processo FAPESP: 12/11074-2 - Modificação de reembasadores resilientes temporários para base de próteses com agentes antimicrobianos: estudos in vitro e in vivo
Beneficiário:Karin Hermana Neppelenbroek
Modalidade de apoio: Auxílio à Pesquisa - Regular
Processo FAPESP: 15/03536-4 - Sorção de água e solubilidade de materiais resilientes temporários para base de prótese
Beneficiário:Giuliana de Campos Chaves Lamarque
Modalidade de apoio: Bolsas no Brasil - Iniciação Científica