ong-Term Evaluation of Poly(lactic acid) (PLA) Implants in a Horse: An Experimental Pilot Stud

Texto completo
Autor(es):
Carvalho, Julia Ribeiro Garcia [1] ; Conde, Gabriel [1] ; Antonioli, Marina Lansarini [1] ; Santana, Clarissa Helena [2] ; Littiere, Thayssa Oliveira [1] ; Dias, Paula Patrocinio [3] ; Chinelatto, Marcelo Aparecido [3] ; Canola, Paulo Alescio [1] ; Zara, Fernando Jose. [1] ; Ferraz, Guilherme Camargo [1]
Número total de Autores: 10
Afiliação do(s) autor(es):
[1] Sao Paulo State Univ UNESP, Sch Agr & Vet Sci FCAV, BR-14884900 Jaboticabal, SP - Brazil
[2] Fed Univ Minas Gerais UFMG, Vet Sch, BR-31270901 Belo Horizonte, MG - Brazil
[3] Univ Sao Paulo, Sao Carlos Sch Engn EESC, BR-13566590 Sao Carlos, SP - Brazil
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: Molecules; v. 26, n. 23 DEC 2021.
Citações Web of Science: 0
Resumo

In horses, there is an increasing interest in developing long-lasting drug formulations, with biopolymers as viable carrier alternatives in addition to their use as scaffolds, suture threads, screws, pins, and plates for orthopedic surgeries. This communication focuses on the prolonged biocompatibility and biodegradation of PLA, prepared by hot pressing at 180 degrees C. Six samples were implanted subcutaneously on the lateral surface of the neck of one horse. The polymers remained implanted for 24 to 57 weeks. Physical examination, plasma fibrinogen, and the mechanical nociceptive threshold (MNT) were performed. After 24, 28, 34, 38, and 57 weeks, the materials were removed for histochemical analysis using hematoxylin-eosin and scanning electron microscopy (SEM). There were no essential clinical changes. MNT decreased after the implantation procedure, returning to normal after 48 h. A foreign body response was observed by histopathologic evaluation up to 38 weeks. At 57 weeks, no polymer or fibrotic capsules were identified. SEM showed surface roughness suggesting a biodegradation process, with an increase in the median pore diameter. As in the histopathological evaluation, it was not possible to detect the polymer 57 weeks after implantation. PLA showed biocompatible degradation and these findings may contribute to future research in the biomedical area. (AU)

Processo FAPESP: 19/16779-3 - Estudo da eficiência e segurança da plataforma vibratória como adjuvante no treinamento de equinos
Beneficiário:Júlia Ribeiro Garcia de Carvalho
Modalidade de apoio: Bolsas no Brasil - Doutorado
Processo FAPESP: 17/10959-4 - Aplicabilidade de biopolímeros implantados em equinos
Beneficiário:Júlia Ribeiro Garcia de Carvalho
Modalidade de apoio: Bolsas no Brasil - Mestrado
Processo FAPESP: 15/26738-1 - Comportamento e biomarcadores musculares de ratos submetidos à síndrome do sobretreinamento (overtraining)
Beneficiário:Guilherme de Camargo Ferraz
Modalidade de apoio: Auxílio à Pesquisa - Regular
Processo FAPESP: 18/13685-5 - Análise integrativa da fauna brasileira de crustáceos decápodes: taxonomia, sistemática filogenética, espermiotaxonomia, morfologia do desenvolvimento pós-embrionário, ecologia e conservação
Beneficiário:Fernando Luis Medina Mantelatto
Modalidade de apoio: Auxílio à Pesquisa - Programa BIOTA - Temático