Compact and autonomous multiwavelength microanalyz... - BV FAPESP
Advanced search
Start date
Betweenand
(Reference retrieved automatically from Web of Science through information on FAPESP grant and its corresponding number as mentioned in the publication by the authors.)

Compact and autonomous multiwavelength microanalyzer for in-line and in situ colorimetric determinations

Full text
Author(s):
da Rocha, Zaira M. [1] ; Martinez-Cisneros, Cynthia S. [2] ; Seabra, Antonio C. [1] ; Valdes, Francisco [3] ; Gongora-Rubio, Mario R. [4] ; Alonso-Chamarro, Julian [2]
Total Authors: 6
Affiliation:
[1] Univ Sao Paulo, Lab Sistemas Integraveis, Sao Paulo - Brazil
[2] Univ Autonoma Barcelona, Grp Sensors & Biosensors, Bellaterra - Spain
[3] Inst Tecnol Laguna, Torreon - Mexico
[4] Inst Pesquisas Tecnol Sao Paulo, Sao Paulo - Brazil
Total Affiliations: 4
Document type: Journal article
Source: LAB ON A CHIP; v. 12, n. 1, p. 109-117, 2012.
Web of Science Citations: 15
Abstract

Nowadays, the attainment of microsystems that integrate most of the stages involved in an analytical process has raised an enormous interest in several research fields. This approach provides experimental set-ups of increased robustness and reliability, which simplify their application to in-line and continuous biomedical and environmental monitoring. In this work, a novel, compact and autonomous microanalyzer aimed at multiwavelength colorimetric determinations is presented. It integrates the microfluidics (a three-dimensional mixer and a 25 mm length ``Z-shape{''} optical flow-cell), a highly versatile multiwavelength optical detection system and the associated electronics for signal processing and drive, all in the same device. The flexibility provided by its design allows the microanalyzer to be operated either in single fixed mode to provide a dedicated photometer or in multiple wavelength mode to obtain discrete pseudospectra. To increase its reliability, automate its operation and allow it to work under unattended conditions, a multicommutation sub-system was developed and integrated with the experimental set-up. The device was initially evaluated in the absence of chemical reactions using four acidochromic dyes and later applied to determine some key environmental parameters such as phenol index, chromium(VI) and nitrite ions. Results were comparable with those obtained with commercial instrumentation and allowed to demonstrate the versatility of the proposed microanalyzer as an autonomous and portable device able to be applied to other analytical methodologies based on colorimetric determinations. (AU)

FAPESP's process: 09/08486-4 - AUTOMONOUS MICROLABORATORIES FOR PHOSPHORUS AND NITROGEN MONITORING IN NATURAL WATERS AND WASTEWATERS
Grantee:Zaira Mendes da Rocha
Support Opportunities: Scholarships in Brazil - Post-Doctoral