Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Online extraction of antihypertensive drugs and their metabolites from untreated human serum samples using restricted access carbon nanotubes in a column switching liquid chromatography system

Texto completo
Autor(es):
de Faria, Henrique Dipe [1] ; Bueno, Carolina Tosin [2] ; Krieger, Jose Eduardo [2] ; Krieger, Eduardo Moacyr [2] ; Pereira, Alexandre Costa [2] ; Junior Lima Santos, Paulo Caleb [2, 3] ; Figueiredo, Eduardo Costa [1]
Número total de Autores: 7
Afiliação do(s) autor(es):
[1] Fed Univ Alfenas UNIFAL MG, Lab Toxicant & Drug Anal, Alfenas, MG - Brazil
[2] Univ Sao Paulo, Heart Inst InCor, Lab Genet & Mol Cardiol, Med Sch, Sao Paulo - Brazil
[3] Fed Univ Sao Paulo EPM UNIFESP, Dept Pharmacol, Sao Paulo - Brazil
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: Journal of Chromatography A; v. 1528, p. 41-52, DEC 15 2017.
Citações Web of Science: 6
Resumo

A novel analytical method was developed to determine 5 antihypertensive drugs of different pharmacological classes (angiotensin-converting enzyme inhibitors, calcium channel blockers, alpha-2 adrenergic receptor agonists, angiotensin II receptor blockers, and aldosterone receptor antagonists) and some of their metabolites in human serum. The untreated samples were directly analyzed in a column switching system using an extraction column packed with restricted access carbon nanotubes (RACNTs) in an ultra-high performance liquid chromatography coupled to a mass spectrometer (UHPLC-MS/MS). The RACNTs column was able to exclude approximately 100% of proteins from the samples in 2.0 min, maintaining the same performance for about 300 analytical cycles. The method was validated in accordance with Food and Drug Administration (FDA) guidelines, being linear for all the determined analytes in their respective analytical ranges (coefficients of determination higher than 0.99) with limits of detection (LODs) and quantification (LOQs) ranging from 0.09 to 10.85 mu g L-1 and from 0.30 to 36.17 mu g L-1, respectively. High recovery values (88-112%) were obtained as well as suitable results for inter and intra-assay accuracy and precision. The method provided an analytical frequency of 5 samples per hour, including the sample preparation and separation/detection steps. The validated method was successfully used to analyze human serum samples of patients undergoing treatment with antihypertensive drugs, being useful for pharmacometabolomic, pharmacogenomic, and pharmacokinetic studies. (C) 2017 Elsevier B.V. All rights reserved. (AU)

Processo FAPESP: 13/09295-3 - Avaliação farmacogenética para fármacos do sistema cardiovascular com foco na implementação
Beneficiário:Paulo Caleb Júnior de Lima Santos
Modalidade de apoio: Auxílio à Pesquisa - Jovens Pesquisadores
Processo FAPESP: 13/24440-0 - Avaliação farmacogenética e farmacometabolômica para fármacos anti-hipertensivos
Beneficiário:Carolina Tosin Bueno
Modalidade de apoio: Bolsas no Brasil - Doutorado Direto