Advanced search
Start date
Betweenand


Solids and metal occurrence in the drinking water in the residuals generated in conventional WTP of complete cycle with daily discharge

Full text
Author(s):
Francisco Gláucio Cavalcante de Souza
Total Authors: 1
Document type: Master's Dissertation
Press: São Carlos.
Institution: Universidade de São Paulo (USP). Escola de Engenharia de São Carlos (EESC/SBD)
Defense date:
Examining board members:
João Sérgio Cordeiro; Marco Antonio Penalva Reali; Bernardo Arantes do Nascimento Teixeira
Advisor: João Sérgio Cordeiro
Abstract

In this work, it was made a data survey about the water treatment and the residuals generated in the settling tanks and filters from the Fonte Luminosa WTA located at Araraquara-SP, a conventional type WTA with high rate settling tanks; aiming to obtain parameters about the quality and quantity of residuals generated at this WTA. The relevant parameters in the residuals generation and composition, like the chemical consume, the operational proceedings and the raw water quality, were evaluated and related to each other. The work was divided in three stages. In the first, it was made the physic and operational characterization from the Fonte Luminosa WTA by means of visits and historical data surveys from the water that enters the WTA, the treated water, the chemicals used and the operational data from the period of 2001 to 2003. In the second stage, it was made a qualitative characterization from the water in several stages of the treatment, with the parameters: pH, apparent color, turbidity and solids; to the residuals generated in the settling tanks and filters, it was also made the qualitative characterization with the parameters: COD, total nitrogen, total phosphate, pH, apparent color, turbidity and solids; and it was made a quantitative characterization for these residuals (measured and estimated by the mass balance). The last stage was the evaluation of the occurrence of metals (Fe, Cd, Zn, Ni, Cu, Pb, Cr and Mg) in the total water treatment and in the residuals. The processes and operations applied in the water treatment have a direct influence in the quality and quantity of the generated wastes. In the observed period, the results show a great similarity between the wastes generated in the high rate settling tanks and filters from this WTA. It was observed a great difference between the residuals generated in conventional settling tanks (São Carlos WTA) and high rate settling tanks (daily discharge). It was observed the occurrence of lead, nickel and chrome in the treated water, with values bigger than the ones fixed by the Portaria nº 518/MS from 03/25/2004 to a drinking water. (AU)