Influence of miniscrew dental root proximity on the stability degree

Full text
Author(s):
Mariana Pracucio Gigliotti
Total Authors: 1
Document type: Master's Dissertation
Press: Bauru.
Institution: Universidade de São Paulo (USP). Faculdade de Odontologia de Bauru (FOB/SDB)
Defense date:
Examining board members:
Guilherme dos Reis Pereira Janson; Arnaldo Pinzan; Fabrício Pinelli Valarelli
Advisor: Guilherme dos Reis Pereira Janson
Abstract

The purpose of this study was to evaluate the influence of the proximity between self-drilling miniscrews and dental roots on the stability degree. The sample consisted of 40 miniscrews inserted in the interradicular septum between maxillary second premolars and first molars to provide skeletal anchorage for anterior retraction. The forty post-surgical radiographs were used to measure the septum width in the insertion site (SWI) and the smallest distance between miniscrew head and dental root (SDR). In this regard, the miniscrews were divided in two categories of groups: according to the septum width in the insertion site, groups G1W (SWI 3mm) and G2W (SWI>3 mm), and according to the miniscrew dental root proximity, groups G1P (SDR0mm) and G2P (SDR>0mm). The mobility degree (MD) was monthly quantified to determine miniscrew stability, and the success rate of these devices was calculated. This study also evaluated the influence of following variables on the stability degree: soft tissue characteristics in the insertion site (attached gingiva, mucogingival junction and alveolar mucosa), sensitivity degree during miniscrew load, plaque amount around miniscrew, insertion height, and total evaluation period. All the groups were compared regarding mobility degree and success rate using t test and Fisher exact test, respectively. The results showed no significant difference in mobility degree and success rate between groups G1W and G2W. The miniscrew dental root proximity did not influence the stability and success rate of this anchorage system when G1P and G2P were compared. The total success rate found was 90% and no variable was associated with the miniscrew failure. Nevertheless, the results showed that greater patient sensitivity degree was associated to the miniscrews mobility and the failure of these anchorage devices happened in a short time after their insertion. (AU)

FAPESP's process: 07/01862-5 - Influence of miniscrew dental root proximity on the stability degree
Grantee:Mariana Pracucio Gigliotti
Support Opportunities: Scholarships in Brazil - Master