Advanced search
Start date
Betweenand


Development of a planar electrochemical sensor modified with 1-2 Diaminobenzene (DAB) for nitrite measuring by automatic FIA.

Full text
Author(s):
Fernando Luis de Almeida
Total Authors: 1
Document type: Master's Dissertation
Press: São Paulo.
Institution: Universidade de São Paulo (USP). Escola Politécnica (EP/BC)
Defense date:
Examining board members:
Sebastião Gomes dos Santos Filho; Mário Ricardo Góngora Rubio; Thiago Regis Longo Cesar da Paixão
Advisor: Sebastião Gomes dos Santos Filho
Abstract

In this Master of Science, it has been developed an electrochemical planar sensor defined with three electrodes for nitrite measuring and its interferents (uric acid, ascorbic acid and paracetamol). In the experimental procedure, it is shown the development of an extracorporis set up (mini-pump, solenoid valves and analysis cell) which is coupled to a system of Flow-injection Analysis (FIA). This work also describes the sensor fabrication using alumina substrates, the standard cleaning of the electrodes, the process to obtain Ag/AgCl reference electrodes in HCl (0.1 mol L-1) and electrochemical activation of the working-electrode surface with H2SO4 (0.1 mol L-1). Following, it is shown the study of drying for electrodes at room temperature with exposition to room light and their characterization using three different methods: i) reversibility test (redox current vs. potential); ii) variation of the potential with the time (thermodynamics degradation coefficient) and iii) variation of the potential with the chloride concentration. Also, it is presented the characterization of the effective exposed area of the working electrode and the results of the deposited 1-2 Diaminobenzene (DAB) is presented as a selective polymer. In addition, the results and discussions of the pseudo-reference (recovered or not with Nafion® 117) are presented. Related to irreversibility is the hysteresis associated to the reference electrodes which resulted in the order of 40 mVAg/AgCl Nafion® 117. The observed thermodynamic potentials were of (100 ± 6) mVAg/AgCl Nafion® 117 for pseudo-electrodes recovered with Nafion® 117. Later on, a careful study of the response to nitrite and to its interferents was performed by means of the DPV technique (Differential Pulse Voltammetry). In order to avoid accelerated degradation (corrosion) of the polymer, measurements were performed at a potential of 0,5 VAg/AgCl Nafion® 117. In this condition, nitrite was monitored using the automatized-FIA (Flow Injection Analysis) for concentration in the range of 50 to 250 mol L-1. The results have shown that the planar amperometric sensor for nitrite measuring is usefull since it was observed excellent performance related to reproducibility (99.66%), sensitivity (90 microA mol-1 L mm-2), selectivity (0.32%), repetibility (91.28%) and stability (15.0 ± 0.3 pA). (AU)