Advanced search
Start date
Betweenand
(Reference retrieved automatically from Web of Science through information on FAPESP grant and its corresponding number as mentioned in the publication by the authors.)

OSL and TL techniques combined in a beryllium oxide detector to evaluate simultaneously accumulated and single doses

Full text
Author(s):
Malthez, Anna L. M. C. [1] ; Freitas, Marcelo B. [2] ; Yoshimura, Elisabeth M. [3] ; Umisedo, Nancy K. [3] ; Button, Vera L. S. N. [1]
Total Authors: 5
Affiliation:
[1] Univ Estadual Campinas, Sch Elect & Comp Engn, Dept Biomed Engn, Sao Paulo - Brazil
[2] Univ Fed Sao Paulo, Hlth Informat Dept, Sao Paulo - Brazil
[3] Univ Sao Paulo, Dept Nucl Phys, Sao Paulo - Brazil
Total Affiliations: 3
Document type: Journal article
Source: Applied Radiation and Isotopes; v. 110, p. 155-159, APR 2016.
Web of Science Citations: 2
Abstract

Optically stimulated luminescence (OSL) and thermoluminescence (TL) are similar techniques widely used in radiation dosimetry. The main difference between these techniques is the stimulus to induce luminescence emission: TL technique uses thermal stimulation, whereas OSL uses optical stimulation. One of the main intrinsic characteristics of the OSL technique is the possibility of reading several times the dosimetric materials with a negligible loss of signal. In the case of BeO, recent studies have shown that TL stimulation up to 250 degrees C does not affect its OSL signal. Taking the advantages of dosimetric characteristics of BeO combined with both techniques, in this study, we demonstrated the possibility of measuring accumulated and single doses in the same BeO-based detector in order to use it to improve individual monitoring of radiation workers exposed to X-ray or gamma-ray fields. Single doses were measured using TL technique by heating the detector up to 250 degrees C, whereas accumulated doses were estimated using OSL technique in the same detector in a relatively short time of optical stimulation. The detectors were exposed to two energies: 28 keV X-rays and 1.25 MeV Co-60 gamma rays. The doses estimated by OSL and TL of BeO (Thermalox 995) were compared with those obtained with LiF (TLD-100) and recorded with a calibrated ionization chamber. The results indicate that combined OSL and TL signals of BeO detectors can provide additional information of accumulated dose, with additional exploration of the advantages of both techniques, such as speed in readouts with OSL, and double-check the doses using TL and OSL intensities from BeO. (C) 2016 Elsevier Ltd. All rights reserved. (AU)

FAPESP's process: 10/16437-0 - Characterization and applications of dosimetric materials using optically stimulated luminescence and complementary techniques
Grantee:Linda Viola Ehlin Caldas
Support Opportunities: Research Projects - Thematic Grants