Advanced search
Start date
Betweenand
(Reference retrieved automatically from Web of Science through information on FAPESP grant and its corresponding number as mentioned in the publication by the authors.)

Fracture load of complete-arch implant-supported prostheses reinforced with nylon-silica mesh: An in vitro study

Full text
Author(s):
Papaiz Goncalves, Fernanda de Cassia [1] ; Amaral, Marina [2] ; Souto Borges, Alexandre Luiz [3] ; Martins Goncalves, Luiz Fernando [4] ; de Arruda Paes-Junior, Tarcisio Jose [3]
Total Authors: 5
Affiliation:
[1] Inst Aeronaut Technol ITA, Postdoctoral Program, Sao Jose Dos Campos - Brazil
[2] Univ Taubate UNITAU, Dept Dent, Dent Prostheses, Taubate - Brazil
[3] Sao Paulo State Univ, UNESP, Inst Sci & Technol, Dept Dent Mat & Prosthodont, Ave Engenheiro Francisco Jose Longo 777, BR-12245000 Sao Jose Dos Campos - Brazil
[4] Inst Aeronaut Technol ITA, Applicat Lab, Engn, Sao Jose Dos Campos - Brazil
Total Affiliations: 4
Document type: Journal article
Source: JOURNAL OF PROSTHETIC DENTISTRY; v. 119, n. 4, p. 606-610, APR 2018.
Web of Science Citations: 0
Abstract

Statement of problem. Complete-arch implant-supported prostheses without a framework have a high risk of failure: a straightforward and inexpensive reinforcement material, such as nylon mesh, could improve their longevity. Purpose. The purpose of this in vitro study was to evaluate a nylon-silica mesh compound on the fracture strength of acrylic resin and the fracture load of complete-arch implant-supported prostheses. Material and methods. Twenty-four complete mandibular arch implant-supported prostheses were divided into 2 groups according to cantilever length (molar and premolar) and subdivided into another 2 subgroups according to the presence or absence of reinforcing mesh. The specimens were submitted to a maximum load-to-fracture test in a universal testing machine, with a 100-N load cell, a 2 mm/min crosshead speed, and a spherical metal tip diameter of 4 mm at different points (molar and premolar). These were submitted to 1-way analysis of variance for repeated measurement and the post hoc Tukey multiple comparison test (alpha=.05). Results. The mean maximum load standard deviation for the molar group was 393.4 +/- 95.0 N with reinforcement and 305.4 +/- 76.3 N without reinforcement (P=.02); and for the premolar group was 1083.3 +/- 283.7 N with reinforcement and 605.3 +/- 90.5 N without reinforcement (P=.001). Conclusions. Reinforcement with nylon mesh increased the mean maximum load of implant supported complete-arch prostheses at both cantilever lengths. The cantilever to the premolar (5 mm) presented the highest maximum load values to fracture. (AU)

FAPESP's process: 11/07334-6 - Influence of a nylon fiber reinforcement in flexural strenght and dimensional alteration of acrylic resins
Grantee:Tarcisio Jose de Arruda Paes Junior
Support Opportunities: Regular Research Grants