STABILIZING SETS OF PROPORTIONAL-RESONANT CONTROLLERS FOR THREE-PHASE VOLTAGE SOURCE INVERTERS WITH A LCL FILTER

Full text
Author(s):
Quinalia, Mateus S. ; Magossi, Rafael F. Q. ; Ferreira, Plinio G. B. ; Machado, Ricardo Q. ; Oliveira, Vilma A. ; IEEE
Total Authors: 6
Document type: Journal article
Source: 2017 XIV BRAZILIAN POWER ELECTRONICS CONFERENCE (COBEP); v. N/A, p. 6-pg., 2017-01-01.
Abstract

Applications with traditional voltage source inverters (VSIs) usually demand low THD output voltage regardless the load. The proportional-resonant (PR) controller have been used instead of a classical proportional integral-derivative (PID) controller to track a sinusoidal reference waveform and improve the dynamical response of a specific VSI. Once the interest of knowing the stabilizing set to the controllers has increased, in this paper it is presented, based on Routh-Hurwitz criterion, the stabilizing set of a system with a PR and a three-phase VSI with a LCL filter. Moreover, the inverter circuitry model and the set of PR-controller gains were validated based on Matlab and PSIM simulation results. (AU)

FAPESP's process: 14/25848-5 - MPPT algorithm for a PV panel based on the Thevenin equivalent obtained via measurements
Grantee:Rafael Fernando Quirino Magossi
Support Opportunities: Scholarships in Brazil - Scientific Initiation
FAPESP's process: 13/20721-4 - Sistem for interconection of distributed generators to the grid: sintesis of micro grids
Grantee:Ricardo Quadros Machado
Support Opportunities: Regular Research Grants