Advanced search
Start date
Betweenand
(Reference retrieved automatically from Web of Science through information on FAPESP grant and its corresponding number as mentioned in the publication by the authors.)

ASSESSMENT OF POLYATOMIC INTERFERENCES ELIMINATION USING A COLLISION REACTION INTERFACE (CRI) FOR INORGANIC ANALYSIS OF FUEL ETHANOL BY ICP-QMS

Full text
Author(s):
Neves, Denise R. [1] ; Amais, Renata S. [2] ; Nobrega, Joaquim A. [2] ; Gomes Neto, Jose A. [1]
Total Authors: 4
Affiliation:
[1] UNESP Univ Estadual Paulista, BR-14801970 Araraquara, SP - Brazil
[2] Univ Fed Sao Carlos, Dept Chem, BR-13560 Sao Carlos, SP - Brazil
Total Affiliations: 2
Document type: Journal article
Source: Analytical Letters; v. 45, n. 9, p. 1111-1121, 2012.
Web of Science Citations: 8
Abstract

The effectiveness of a collision-reaction interface (CRI) as instrumental device and the addition of oxygen in the composition of auxiliary gas were evaluated to minimize polyatomic species generated in plasma gas caused by direct introduction of fuel ethanol samples through spray chambers in inductively coupled plasma quadrupole mass spectrometry (ICP-QMS). The oxygen flow-rate was optimized as a compromise among signal counts, signal to background ratio (SBR), and background equivalent concentration (BEC). For 12.5mL min(-1) O-2, ethanol samples diluted 20 times were introduced into the plasma and deposits of carbon compounds on the sampler and/or skimmer cones were not observed. The performance of CRI using H-2 and He inserted through the sampler or skimmer cones was evaluated. Hydrogen gas added through the skimmer cone was more efficient to reduce blank and BEC values. This strategy was necessary to eliminate spectral interferences caused by (Ar12C+)-Ar-40, Ar-40(16) O+, (CO+)-C-12-O-16, C-12(2)+ at isotopes Cr-52(+), Fe-56(+), Si-28(+) and Mg-24(+), respectively. Using matrix-matching calibration and Y internal standard, the optimized method was applied to the determination of Al, Ba, Co, Cr, Cu, Fe, Mg, Mn, Mo, Na, Ni, Pb, Sb, Si, V, and Zn in fuel ethanol. Accuracy of developed method was checked after addition/recovery tests. Recoveries and RSD (n = 12) for all elements varied within the 78-114% and 0.4-2% ranges, respectively. Limits of detection for all elements obtained by combining CRI and ICP-QMS were always better than 0.80 mu g L-1 except for Si at 14 mu g L-1. (AU)

FAPESP's process: 06/59083-9 - Inductively coupled plasma mass spectrometry: fundamentals and applications
Grantee:Joaquim de Araújo Nóbrega
Support Opportunities: Research Projects - Thematic Grants