Advanced search
Start date
Betweenand
(Reference retrieved automatically from SciELO through information on FAPESP grant and its corresponding number as mentioned in the publication by the authors.)

Echobiometrics kidney and renal artery triplex doppler of canine fetuses

Full text
Author(s):
M.A.R. Feliciano [1] ; D.J. Cardilli [2] ; A.C. Nepomuceno [3] ; R.M. Crivalero [4] ; M.A.M. Silva [5] ; L.N. Coutinho [6] ; M.E.F. Oliveira [7] ; W.R.R. Vicente [8]
Total Authors: 8
Affiliation:
[1] Unesp. Faculdade de Ciências Agrárias e Veterinárias
[2] Unesp. Faculdade de Ciências Agrárias e Veterinárias
[3] Unesp. Faculdade de Ciências Agrárias e Veterinárias
[4] Unesp. Faculdade de Ciências Agrárias e Veterinárias
[5] Unesp. Faculdade de Ciências Agrárias e Veterinárias
[6] Unesp. Faculdade de Ciências Agrárias e Veterinárias
[7] Unesp. Faculdade de Ciências Agrárias e Veterinárias
[8] Unesp. Faculdade de Ciências Agrárias e Veterinárias
Total Affiliations: 8
Document type: Journal article
Source: Arquivo Brasileiro de Medicina Veterinária e Zootecnia; v. 66, n. 2, p. 445-449, 2014-04-00.
Abstract

The aim of this study was to assess the sogographic parameters and biometry of canine fetal kidneys using the B mode, and to determinate the vascular index of the fetal renal arteries using the Doppler Triplex. Twenty four Shi-tzu and Pug, weighting between 4 and 10kg, aging between 4 and 6 years old were evaluated. The B mode, the fetal renal echobiometry and regularity of the renal surface, echotexture and cortex:medular ratio were evaluated during the 5th, 6th, 7th and 8th weeks of pregnancy. At the same time point of the B mode evaluation, the Doppler Triplex was carried out to assess the sistolic peak velocity (SPV), end diastolic velocity (EDV), vascular resistive (RI) and pulsatility index (PI). B mode revealed no fetal renal abnormalities and echobiometry showed important measurements during fetal development (P<0.0001). The values of the fetal renal arteries index (PSV and EDV) increased during the course of the pregancy (P<0.05) and remained constant for PI and RI (P>0.05). B mode and Doppler Triplex were important tools for the assessment of fetal renal development, using echobiometry and renal arterial index in canie fetuses. (AU)

FAPESP's process: 10/16913-7 - Conventional ultrassonography and Dopplerflow maternal fetal prenatal in evaluation of pregnant bitches
Grantee:Marcus Antônio Rossi Feliciano
Support Opportunities: Scholarships in Brazil - Post-Doctoral