Advanced search
Start date
Betweenand
(Reference retrieved automatically from SciELO through information on FAPESP grant and its corresponding number as mentioned in the publication by the authors.)

Detecting alterations of glucose and lipid components in human serum by near-infrared Raman spectroscopy

Full text
Author(s):
Rita de Cássia Fernandes Borges [1] ; Ricardo Scarparo Navarro [2] ; Hector Enrique Giana [3] ; Fernanda Grubisich Tavares [4] ; Adriana Barrinha Fernandes [5] ; Landulfo Silveira Junior [6]
Total Authors: 6
Affiliation:
[1] Universidade Camilo Castelo Branco. Biomedical Engineering Institute - Brasil
[2] Universidade Camilo Castelo Branco. Biomedical Engineering Institute - Brasil
[3] Laboratório de Análises Clínicas Oswaldo Cruz - Brasil
[4] Laboratório de Análises Clínicas Oswaldo Cruz - Brasil
[5] Universidade Camilo Castelo Branco. Biomedical Engineering Institute - Brasil
[6] Universidade Camilo Castelo Branco. Biomedical Engineering Institute - Brasil
Total Affiliations: 6
Document type: Journal article
Source: Res. Biomed. Eng.; v. 31, n. 2, p. 160-168, 2015-04-00.
Abstract

Introduction Raman spectroscopy may become a tool for the analysis of glucose and triglycerides in human serum in real time. This study aimed to detect spectral differences in lipid and glucose components of human serum, thus evaluating the feasibility of Raman spectroscopy for diagnostic purposes. Methods A total of 44 samples of blood serum were collected from volunteers and submitted for clinical blood biochemical analysis. The concentrations of glucose, cholesterol, triglycerides, and low-density and high-density lipoproteins (LDL and HDL) were obtained using standard biochemical assays. Serum samples were placed in Eppendorf tubes (200 µL), kept cooled (5 °C) and analyzed with near-infrared Raman spectroscopy (830 nm, 250 mW, 50 s accumulation). The mean spectra of serum with normal or altered concentrations of each parameter were compared to determine which Raman bands were related to the differences between these two groups. Results Differences in peak intensities of altered sera compared to normal ones depended on the parameter under analysis: for glucose, peaks were related to glucose; for lipid compounds the main changes occurred in the peaks related to cholesterol, lipids (mainly triolein) and proteins. Principal Components Analysis discriminated altered glucose, cholesterol and triglycerides from the normal serum based on the differences in the concentration of these compounds. Conclusion Differences in the peak intensities of selected Raman bands could be seen in normal and altered blood serum samples, and may be employed as a means of diagnosis in clinical analysis. (AU)

FAPESP's process: 09/01788-5 - Dispersive Raman spectroscopy using optical fibers "Raman probe" applied to the diagnosis of neoplasia in the skin and prostate
Grantee:Landulfo Silveira Junior
Support Opportunities: Regular Research Grants