Advanced search
Start date
Betweenand
(Reference retrieved automatically from Web of Science through information on FAPESP grant and its corresponding number as mentioned in the publication by the authors.)

Diagnosis of alveolar and root fractures in macerated canine maxillae: a comparison between two different CBCT protocols

Full text
Author(s):
Kobayashi-Velasco, Solange ; Salineiro, Fernanda C. S. ; Gialain, Ivan O. ; Cavalcanti, Marcelo G. P.
Total Authors: 4
Document type: Journal article
Source: Dentomaxillofacial Radiology; v. 46, n. 6 2017.
Web of Science Citations: 2
Abstract

Objectives: To compare two small-field-of-view (FOV) CBCT protocols with different voxel sizes and number of frames for the diagnosis of root and alveolar fractures in macerated canine maxillae. Methods: 80 incisor teeth from the canine species were inserted in 80 anterior alveolar sockets of 20 canine maxillae. An operator randomly divided each maxilla site (80 sites in total) into 4 equal groups of 20 sites: 1 (sound tooth and non-fractured alveolar socket); 2 (sound tooth and fractured alveolar socket); 3 (fractured root and non-fractured alveolar socket); and 4 (fractured root and fractured alveolar socket). The CBCT images were obtained using two different protocols: normal (N) (voxel 0.20 mm, 400 frames and radiation exposure 5.6 mGy) and high definition (HD) (voxel 0.15 mm, 500 frames and radiation exposure 7.0 mGy). Results: Sensitivity numbers for alveolar fractures were lower than specificity, resulting in comparable areas under the receiver operating characteristic curves (AUC) for both protocols. Sensitivity, specificity and AUC for N and HD protocols were very similar for root fractures. When comparing AUC for both N and HD protocols by submitting them to Student's t-test, the comparison among the curves produced statistically non-significant results for alveolar fractures and root fractures likewise. Conclusions: Our findings demonstrated that the elected protocol for the diagnosis of root and alveolar fractures was N. This protocol allowed similar diagnosis results than HD protocol; however, with a lower amount of radiation exposure for the patient (5.6 mGy for N vs 7.0 mGy for HD). (AU)

FAPESP's process: 09/53982-0 - Acquisition of super high-resolution computed tomography equipment for evaluating and measuring bone structures and dental bone in three-dimensional images in clinical research in dentistry
Grantee:Marina Helena Cury Gallottini
Support Opportunities: Multi-user Equipment Program