Advanced search
Start date
Betweenand
(Reference retrieved automatically from Web of Science through information on FAPESP grant and its corresponding number as mentioned in the publication by the authors.)

Synergistic effect of reduced graphene oxide/azo-polymer layers on electrochemical performance and application as nonenzymatic chemiresistor sensors for detecting superoxide anion radicals

Full text
Author(s):
Olean-Oliveira, Andre [1] ; Pacheco, Jessica C. [1] ; Seraphim, Patricia M. [2] ; Teixeira, Marcos F. S. [1]
Total Authors: 4
Affiliation:
[1] Sao Paulo State Univ UNESP, Sch Sci & Technol, Dept Chem & Biochem, Rua Roberto Simonsen 305, BR-19060900 Presidente Prudente, SP - Brazil
[2] Sao Paulo State Univ UNESP, Dept Physiotherapy, Sch Sci & Technol, Presidente Prudente, SP - Brazil
Total Affiliations: 2
Document type: Journal article
Source: JOURNAL OF ELECTROANALYTICAL CHEMISTRY; v. 852, NOV 1 2019.
Web of Science Citations: 2
Abstract

The present paper describes a nonenzymatic chemiresistor sensor based on an azo-polymer and reduced graphene oxide (rGO) as a resistive platform for superoxide radical detection. The sensorial platform was prepared on layer-by-layer-assembled films of poly(azo-Bismarck Brown Y) and reduced graphene oxide by cyclic voltammetry. The nanocomposite film exhibited interesting synergetic properties based on the redox properties of the azo-polymer combined with the good electronic conductivity and stability of graphene. The electrical conductivity mechanism of the graphene-polymer was analyzed by electrochemical impedance and compared to that of an electrode coated with only polymer. The conductance properties of the interlayer formed by pi-pi stacking between the conjugated structure of the polymer chains and the structure of the graphene sheet are dependent on the applied potential of the system. The performance of the poly(azo-BBY)/rGO film as a chemiresistor material for the sensing of superoxide anions was evaluated by impedance measurements at the applied potential of +0.30 in PBS (7.4). The charge transfer resistance values change substantially in the presence of superoxide in solution. The effect of superoxide on the resistivity of the device is attributed to changes in the oxidation state of the polymer. The impedance measurements in real time (chrono-impedance) with the poly(azo-BBY)/rGO sensor with different superoxide concentrations revealed good linearity behavior between the real impedance and the superoxide anion concentration (0.12-2.6 mmol L-1) with a detection limit of 81.0 mu mol(-1). (AU)

FAPESP's process: 16/09017-1 - STUDY OF THE FILM FORMATION OF SCHIFF BASE METALLIC COMPLEXES
Grantee:Marcos Fernando de Souza Teixeira
Support Opportunities: Regular Research Grants