Advanced search
Start date
Betweenand
(Reference retrieved automatically from Web of Science through information on FAPESP grant and its corresponding number as mentioned in the publication by the authors.)

Fast construction of polymer monolithic columns inside fluorinated ethylene propylene (FEP) tubes for separation of proteins by reversed-phase liquid chromatography

Full text
Author(s):
do Nascimento, Fernando H. [1] ; Moraes, Amanda H. [1] ; Trazzi, Catharina R. L. [1] ; Velasques, Caryna M. [1] ; Masini, Jorge C. [1]
Total Authors: 5
Affiliation:
[1] Univ Sao Paulo, Inst Quim, Dept Quim Fundamental, Av Prof Lineu Prestes 748, BR-05508000 Sao Paulo, SP - Brazil
Total Affiliations: 1
Document type: Journal article
Source: Talanta; v. 217, SEP 2020.
Web of Science Citations: 0
Abstract

This paper describes the preparation of polymer monolithic columns in the confines of fluorinated ethylene propylene (FEP) tubes. These tubes are cheap, chemically stable, and widely used in flow analysis laboratories. UV-initiated grafting with 5 wt% benzophenone in methanol for 1 h activated the internal surface walls, thus enabling the further covalent binding of ethylene glycol dimethacrylate (EDMA) from a 15 wt% solution in methanol, also via photografting. Both steps used 254 nm radiation under a potency of 120 mJ cm(2). ATR-FTIR measurements revealed the presence of carbonyl, alkyl and vinyl groups in the functionalized FEP. The density of vinyl groups was high enough to firmly attach a poly(lauryl methacrylate-co-ethylene glycol dimethacrylate) monolith in 120 x 1.57 mm i.d. tubes, prepared via photopolymerization. The total preparation lasts less than 2-h. The columns were permeable, (1.58 +/- 0.06) x 10(-13) m(2), providing reproducible chromatographic parameters of retention times, retention factor, selectivity, and resolution. The monoliths were stable at flow rates of 500 mu L min(-1), collapsing only at flow rates > 700 mu L min(-1), a condition that increased the backpressure over 1000 psi (experiments at the room temperature). The separation of proteins by reversed-phase liquid chromatography demonstrated the efficiency of the columns. Determination of egg white proteins (ovalbumin and lysozyme) and myoglobin in spiked urine proved the applicability to the analysis of real samples. (AU)

FAPESP's process: 13/18507-4 - Porous monolithic materials for chromatographic separations and sample preparation
Grantee:Jorge Cesar Masini
Support Opportunities: Regular Research Grants