Advanced search
Start date
Betweenand
(Reference retrieved automatically from Web of Science through information on FAPESP grant and its corresponding number as mentioned in the publication by the authors.)

Elastography acoustic radiation force impulse (ARFI): an investigation of ocular elasticity in dogs with chronic secondary glaucoma

Full text
Author(s):
Show less -
Madruga, Gabriela Morais [1] ; Rossi Feliciano, Marcus Antonio [2, 1] ; Maronezi, Marjury Cristina [1] ; Filezio, Marcella Rosa [1] ; Morato Abreu, Thais Guimaraes [1] ; Ribeiro, Alexandre Pinto [2] ; Fachini, Francimery Aparecida [1] ; Kobashigawa, Kamachi [1] ; Kniphoff da Cruz, Igor Cezar [1] ; Ramirez Uscategui, Ricardo Andres [3] ; Laus, Jose Luiz [1]
Total Authors: 11
Affiliation:
[1] Paulista State Univ Julio de Mesquita Filho UNESP, Fac Agr & Vet Sci, Jaboticabal - Brazil
[2] Fed Univ Santa Maria UFSM, Santa Maria, RS - Brazil
[3] Fed Univ Vale Jequitinhonha & Mucuri, Intitute Agr Sci, Unai - Brazil
Total Affiliations: 3
Document type: Journal article
Source: TURKISH JOURNAL OF VETERINARY & ANIMAL SCIENCES; v. 45, n. 3, p. 404-410, 2021.
Web of Science Citations: 0
Abstract

The aim of this study was to evaluate and compare the elasticity of the optic nerve (ON) and retinal-choroid-sclera complex (RCSC) in dogs with healthy eyes and secondary glaucoma using ARFI elastography. ARFI elastography was performed on normal eyes (n = 25) and affected by glaucoma (n = 25). The mean values of shear wave velocity (SWV) of the ON and RCSC were compared between groups by the Student's t-test. The correlation between elastography measurements of the ON and RCSC and the intraocular pressure (IOP) was measured. The SWV of the optic nerve in glaucomatous eyes (4.77 +/- 1.59 m/s) was being significantly higher than in healthy eyes (2.34 +/- 0.45 m/s) (p < 0.0001). RCSC shear wave velocity values in glaucomatous and healthy eye were 4.26 +/- 1.28 m/s and 2.36 +/- 0.40 m/s, respectively, demonstrating increased stiffness in the glaucomatous group (p < 0.0001). RCSC and ON shear wave velocity did not correlate with size of the vitreous chamber and ON as measured by B-mode ultrasound (p > 0.05). However, there was a slight positive correlation between RCSC and ON shear velocity in the glaucoma group (r = 0.38; p = 0.05). The shear wave velocity rate values of ON and RCSC tissues in glaucomatous eyes are greater than in healthy eyes, suggesting that they are less elastic, or harder, in glaucomatous eyes. (AU)

FAPESP's process: 17/14957-6 - Study of new biotechnics for reproduction of canine and small ruminants
Grantee:Wilter Ricardo Russiano Vicente
Support Opportunities: Research Projects - Thematic Grants
FAPESP's process: 19/15282-8 - MUE granted in the process 17/14957-6: Siemens S2000
Grantee:Wilter Ricardo Russiano Vicente
Support Opportunities: Multi-user Equipment Program