Advanced search
Start date
Betweenand
(Reference retrieved automatically from Web of Science through information on FAPESP grant and its corresponding number as mentioned in the publication by the authors.)

Gel and thermoluminescence dosimetry for dose verifications of a real anatomy simulated prostate conformal radiation treatment in the presence of metallic femoral prosthesis

Full text
Author(s):
Rojas, Diana M. C. [1] ; Pavoni, Juliana F. [1] ; Arruda, Gustavo V. [2] ; Baffa, Oswaldo [1]
Total Authors: 4
Affiliation:
[1] Univ Sao Paulo, Fac Philosophy Sci & Letters, Dept Phys, Ribeirao Preto, SP - Brazil
[2] Univ Sao Paulo, Ribeirao Preto Med Sch, Ribeirao Preto, SP - Brazil
Total Affiliations: 2
Document type: Journal article
Source: JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS; AUG 2021.
Web of Science Citations: 0
Abstract

This study aims to verify the dose delivery of prostate radiotherapy treatments in an adult pelvic phantom with two metallic hip and femur prosthesis using a four-field box technique. The prostate planned target volume (PTV) tridimensional (3D) dose distribution was evaluated using gel dosimetry, and thermoluminescent dosimeters (TLD) were used for point-dose measurements outside it. Both results were compared to the treatment planning system (TPS) dose calculation without using heterogeneity corrections to evaluate the influence of the metal in the dose distribution. MAGIC-f gel dosimeter (Methacrylic and Ascorbic acid in Gelatin Initiated by Copper with Formaldehyde) associated with magnetic resonance imaging was used. TLD were positioned at several points at the bone metal interface and the sacrum region. The comparison of the gel measured and the TPS calculated dose distributions were done using gamma analysis (3%/3 mm), and a pass rate of 93% was achieved. The TLD dose values at the bone-metal interface showed variations from the planned dose. However, at the sacrum region, where the beams did not intercept the prosthesis, there was a good agreement between TPS planning and TLD measurements. Our results show how the combination of 3D dosimetry and measurements at specific points in the phantom allowed a comprehensive view of the dose distribution and identified that care must also be paid to regions outside the PTV. (AU)

FAPESP's process: 21/02254-6 - Applications of machine learning tools in radiotherapy
Grantee:Juliana Fernandes Pavoni
Support Opportunities: Regular Research Grants
FAPESP's process: 13/07699-0 - Research, Innovation and Dissemination Center for Neuromathematics - NeuroMat
Grantee:Oswaldo Baffa Filho
Support Opportunities: Research Grants - Research, Innovation and Dissemination Centers - RIDC