Advanced search
Start date
Betweenand
(Reference retrieved automatically from Web of Science through information on FAPESP grant and its corresponding number as mentioned in the publication by the authors.)

Evaluation of Torsional Resistance and Bending Stiffness of Coronal Flaring Nickel-Titanium Instruments

Full text
Author(s):
Weissheimer, Theodoro [1] ; Alcalde, Murilo Priori [2] ; Cortez, Julia Barrionuevo [2] ; da Rosa, Ricardo Abreu [1] ; Vivan, Rodrigo Ricci [3] ; Souza Calefi, Pedro Henrique [3] ; Hungaro Duarte, Marco Antonio [3] ; Reis So, Marcus Vinicius [1]
Total Authors: 8
Affiliation:
[1] Univ Fed Rio Grande do Sul, Dept Conservat Dent, Porto Alegre, RS - Brazil
[2] Univ Sagrado Coracao, Dept Hlth, Sci Ctr, Bauru, SP - Brazil
[3] Univ Sao Paulo, Bauru Fac Dent, Endodont & Dent Mat, Dept Operat Dent, Bauru, SP - Brazil
Total Affiliations: 3
Document type: Journal article
Source: EUROPEAN ENDODONTIC JOURNAL; v. 6, n. 3, p. 284-289, 2021.
Web of Science Citations: 0
Abstract

Objective:The aim of this study was to evaluate the bending and torsional resistance of the following instruments: Mtwo 25/.07 (MT - VDW, Munich, Germany), Navigator W-XN 25.07 (WXN - Wizard Navigator, Medin, Nove Mesto na Morave, Czech Republic), ProTaper Universal SX 19/.04 (PSX - Dentsply Tulsa Dental Specialties, Tulsa, USA), MK Orifice Shapper 17/.08 (OS - MK Life Medical and Dental Products, Porto Alegre, Brazil) and MK Sequence 17.12 (MKS - MK Life Medical and Dental Products, Porto Alegre, Brazil). Methods: One hundred instruments were used (n=20). Resistance to bending (n=10), torque and angular deflection (n=10) at the failure of new instruments were measured according to ISO 3630-1. Metal mass volume at 3 mm from the tip was evaluated using micro-computed tomography (micro-CT). The fractured surface of each fragment was examined by scanning electron microscopy (SEM). Data were analysed using 1-way analysis of variance and Tukey tests. Results: Torsional resistance values of MK Sequence were higher than the other groups (P<0.05). No differences were observed among MT, WXN and OS (P>0.05) and PTS, which presented the lowest values (P<0.05). MT showed the highest angular deflection (P<0.05). WXN and PSX presented no significant difference (P>0.05). PSX and OS also showed no significant differences (P>0.05). MKS instruments had the lowest angular deflection values (P<0.05). There were significant differences among all the groups in bending stiffness test (P<0.05), but PSX had the lowest torque to bend (P<0.05). MKS had the larger metal mass volume at 3 mm from the tip (P<0.05). SEM analysis showed similar and typical features of torsional failure for all instruments tested. Conclusion: In conclusion, MK Sequence 17/.12 had the highest torsional fracture resistance. Mtwo 25/.07 showed higher angular deflection capacity, and ProTaper Universal SX the 19/.04 lower bending stiffness. (AU)

FAPESP's process: 18/23452-8 - Evaluation of the torsion and flexural strength of nickel-titanium rotary instruments used for the cervical preparation of the root canals
Grantee:Júlia Barrionuevo Cortez
Support Opportunities: Scholarships in Brazil - Scientific Initiation