Advanced search
Start date
Betweenand


Contactless conductometric biosensor in microchip containing folic acid as bioreceptor

Full text
Author(s):
Renato Sousa Lima
Total Authors: 1
Document type: Master's Dissertation
Press: São Carlos.
Institution: Universidade de São Paulo (USP). Instituto de Química de São Carlos (IQSC/BT)
Defense date:
Examining board members:
Emanuel Carrilho; Susana Ines Cordoba de Torresi; Valtencir Zucolotto
Advisor: Emanuel Carrilho
Abstract

This work describes the development of a biosensor containing capacitively coupled contactless conductivity transduction (C4D) and folic acid (FA) as bioreceptor in microchip, a new alternative that can be used in FR-α tumor biomarker analysis. FR-α exhibits highly specific interactions with FA, showing formation constants of the order of 109-1010. The microfluidic devices consisted of a glass layer (integrating the electrodes), dielectric (containing the biosensor phase), and poly(dimetilsiloxane) substrate (PDMS, incorporating microchannel). The microfabrication stage evolved photolithography processes, metal adsorption via sputtering, and plasma-enhanced vapor film deposition. In order to improve detection levels of C4D, sensitivity studies were conducted by changing the dielectric nature and electrode configuration. Through flow analysis with given electrolyte standards, the limits of detection and quantification were calculated based on analytical curve parameters. Subsequently, researches were performed to characterize the modified surfaces with immobilization intermediate considering reaction conditions distinct (reagent, concentration, solvent, and time). The techniques of scanning electron microscopy and X-ray photoelectron spectroscopy were employed, respectively, aiming to verify the clusters formation and allow qualitative and quantitative determinations about the surfaces chemical composition. From the results of sensitivity experiments and surface characterization, we adopt the following parameters for the biomolecular interactions assays: SiO2 film as dielectric, C4D selective electrodes with rectangular shape and antiparallel orientation, and self-assembled monolayers of 3-aminopropyl(triethoxysilane) as intermediary for immobilization of FA. The two final steps of the work were: optimizing the FA functionalization time (3, 5, and 7 h) and phase biosensor characterization, made from measures of C4D and atomic force microscopy (AFM). For the first case, due to the absence of FR-α standard for purchase, the microchips were applied to FA specific monoclonal antibody (α-FA). The biomolecular assay indicated effective adsorption of FA, without occurrence (at least in significant levels) of steric hindrance of its bioactive specie. Among the investigated times of functionalization, 3 h resulted in a higher sensitivity of the method. In terms of biosensor phase electrochemical characterization stage, their results evidenced correlation between analytical response and FA/α-FA interactions. Additionally, as the AFM measurements showed, drastic changes in the morphology of the substrate (SiO2) with the surface modification processes did not occur. Finally, the use of the C4D as transduction technical in biosensors proved to be a promissory alternative for FR-α tumor biomarker analysis. Among other features, this platform has not drawbacks related to the electrode/solution contact, dispenses the use of redox mediators, allows the simultaneous determination of multianalytes, and employs an instrumentation that is simple, cheap, and portable. Nevertheless, changes in the transducer should be implemented to increase the method sensitivity, which represents its main limiting factor. (AU)

FAPESP's process: 08/07597-4 - A microsystem containing contactless conductometric biosensor for analysis of the FR-± cancer biomarker
Grantee:Renato Sousa Lima
Support Opportunities: Scholarships in Brazil - Master