Advanced search
Start date
Betweenand
(Reference retrieved automatically from Web of Science through information on FAPESP grant and its corresponding number as mentioned in the publication by the authors.)

The 3-min all-out test is valid for determining critical power but not anaerobic work capacity in tethered running

Full text
Author(s):
Traina Gama, Maria Carolina [1] ; Masselli dos Reis, Ivan Gustavo [1] ; de Barros Sousa, Filipe Antonio [1] ; Gobatto, Claudio Alexandre [1]
Total Authors: 4
Affiliation:
[1] Univ Campinas UNICAMP, Sch Appl Sci, Limeira, SP - Brazil
Total Affiliations: 1
Document type: Journal article
Source: PLoS One; v. 13, n. 2 FEB 14 2018.
Web of Science Citations: 1
Abstract

The purpose of the study was to investigate if the 3-min all-out test (3MT) is valid for obtaining critical power intensity (CP) and the amount of work that can be performed above CP (W') on non-motorized treadmills in tethered running. Eight physically active individuals (24 +/- 3 years; 78.3 +/- 8.7 kg; 179 +/- 5 cm; 9.0 +/- 2.5% body fat) performed four different efforts at constant intensity to exhaustion in order to determine CP and W'. The mechanical power values obtained were subsequently plotted with their corresponding time to exhaustion (limit time) for application of three mathematical models: power hyperbolic versus time limit (Hyp), linear power versus 1/time (P vs 1/t) and linear work versus time limit (vs t). The 3MT test was carried out on the last day to determine end power (EP) and anaerobic capacity (WEP) using this methodology. EP value of 181.7 +/- 52 was similar (p = 0.486) to 178.2 +/- 61 (CP Hyp), 191.4 +/- 55 (vs t) and 188.3 +/- 55 (P vs 1/t). WEP value of 17.9 +/- 4.8 was not similar (p = 0.000) to 50.2 +/- 15.3 (CP Hyp), 44.8 +/- 8.7 (vs t) and 45.5 +/- 8.4 (P vs 1/t). Positive results (r = 0.78 +/- 0.98 and ICC = 0.88 +/- 0.99) of Pearson correlation and intraclass correlation (ICC +/- absolute agreement) were found for aerobic applications of conventional CP and 3MT. For anaerobic data, only the three models of conventional CP were correlated (r = 0.76 +/- 0.93); however, W' from the three models was not correlated with WEP (r = 0.37 +/- 0.52). The results of this study suggest that 3MT in tethered running on non-motorized treadmills is a valid test for estimating CP aerobic parameters in a single day of application but not anaerobic parameters of W'. (AU)

FAPESP's process: 09/08535-5 - Standardization and validity of aerobic and anaerobic tests in field and laboratory, using free, tethered and half-tethered running, in endurance and sprint runners
Grantee:Claudio Alexandre Gobatto
Support Opportunities: Regular Research Grants