Advanced search
Start date
Betweenand


Lung nodule volumetry accuracy and precision on energy-integrating and CdZnTe photon-counting CT technologies

Full text
Author(s):
Costa, Paulo R. ; Pimenta, Elsa B. ; Oostveen, Luuk J. ; Boiset, Gisell R. ; Moura, Raissa A. S. ; Sechopoulos, Ioannis
Total Authors: 6
Document type: Journal article
Source: MEDICAL IMAGING 2025: PHYSICS OF MEDICAL IMAGING, PT 1; v. 13405, p. 5-pg., 2025-01-01.
Abstract

Nodule volume doubling time is an important biomarker for lung cancer diagnosis, making accurate estimation of nodule volume in low-dose CT images crucial. Hence, the purpose of this work was to evaluate the precision and accuracy of volume measurements of solid nodules (SN) and ground glass opacities (GGO) in images acquired using conventional energy-integrating (EICT) and CdZnTe photon-counting CT (PCCT) systems, reconstructed using hybrid iterative (HIR) and deep-learning based (DLR) reconstructions. For this, a patient-based anthropomorphic 3D printed lung phantom, five printed SNs of different sizes, and four handmade GGOs were designed, constructed, and validated. To verify the real volumes (i.e., ground truth) of the nodules, ultra-high-resolution images were acquired using a mu CT system. CT images of the phantom were acquired with a CTDIvol of 1.4 mGy. Ten acquisitions were performed per scanner/protocol combination with phantom repositioning to mimic clinical positioning variations. EICT images were reconstructed in normal resolution using HIR. The PCCT images were reconstructed in both normal and high resolution (HR) with HIR and DLR. The relative error (RE) and the coefficient of variation (CV) were used to evaluate the accuracy and precision of the volume estimates, respectively. The choice of reconstruction method and kernel combination is critical in both systems, affecting both precision and accuracy. When comparing EICT and PCCT systems using the combination DLR/Lung kernel, PCCT demonstrates better accuracy (RE < 14% for SN and < 8.1% for GGO) and precision (CV < 5% for SN). (AU)

FAPESP's process: 23/03945-8 - Development, validation and application of techniques for evaluation of low dose tomographic protocols
Grantee:Paulo Roberto Costa
Support Opportunities: Scholarships abroad - Research
FAPESP's process: 18/05982-0 - R&D&I in radiation metrology in the health area
Grantee:Linda Viola Ehlin Caldas
Support Opportunities: Research Projects - Thematic Grants
FAPESP's process: 21/14688-0 - Development and validation of materials radiologically equivalent to human tissues for ionizing radiation dosimetry and quality control
Grantee:Gisell Ruiz Boiset
Support Opportunities: Scholarships in Brazil - Post-Doctoral
FAPESP's process: 22/11457-0 - Applications of additive manufacturing techniques to the development of computed tomography phantoms
Grantee:Paulo Roberto Costa
Support Opportunities: Regular Research Grants