Advanced search
Start date
Betweenand
(Reference retrieved automatically from Web of Science through information on FAPESP grant and its corresponding number as mentioned in the publication by the authors.)

The effect of osseodensification drilling for endosteal implants with different surface treatments: A study in sheep

Full text
Author(s):
Lahens, Bradley [1] ; Lopez, Christopher D. [1] ; Neiva, Rodrigo F. [2] ; Bowers, Michelle M. [1] ; Jimbo, Ryo [3] ; Bonfante, Estevam A. [4] ; Morcos, Jonathan [1] ; Witek, Lukasz [1] ; Tovar, Nick [1] ; Coelho, Paulo G. [1, 5]
Total Authors: 10
Affiliation:
[1] NYU, Coll Dent, Dept Biomat & Biomimet, New York, NY 10010 - USA
[2] Univ Florida, Dept Periodontol, Coll Dent, Gainesville, FL 32610 - USA
[3] Malmo Univ, Fac Odontol, Dept Oral & Maxillofacial Surg & Oral Med, Malmo - Sweden
[4] Univ Sao Paulo, Bauru Sch Dent, Dept Prosthodont & Periodontol, Bauru, SP - Brazil
[5] NYU, Sch Med, Hansjorg Wyss Dept Plast Surg, New York, NY 10016 - USA
Total Affiliations: 5
Document type: Journal article
Source: JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS; v. 107, n. 3, p. 615-623, APR 2019.
Web of Science Citations: 0
Abstract

This study investigated the effects of osseodensification drilling on the stability and osseointegration of machine-cut and acid-etched endosteal implants in low-density bone. Twelve sheep received six implants inserted into the ilium, bilaterally (n=36 acid-etched, and n=36 as-machined). Individual animals received three implants of each surface, placed via different surgical techniques: (1) subtractive regular-drilling (R): 2.0 mm pilot, 3.2 and 3.8 mm twist drills); (2) osseodensification clockwise-drilling (CW): Densah Bur (Versah, Jackson, MI) 2.0 mm pilot, 2.8, and 3.8 mm multifluted tapered burs; and (3) osseodensification counterclockwise-drilling (CCW) Densah Bur 2.0 mm pilot, 2.8 mm, and 3.8 mm multifluted tapered burs. Insertion torque was higher in the CCW and CW-drilling compared to the R-drilling (p<0.001). Bone-to-implant contact (BIC) was significantly higher for CW (p=0.024) and CCW-drilling (p=0.006) compared to the R-drilling technique. For CCW-osseodensification-drilling, no statistical difference between the acid-etched and machine-cut implants at both time points was observed for BIC and BAFO (bone-area-fraction-occupancy). Resorbed bone and bone forming precursors, preosteoblasts, were observed at 3-weeks. At 12-weeks, new bone formation was observed in all groups extending to the trabecular region. In low-density bone, endosteal implants inserted via osseodensification-drilling presented higher stability and no osseointegration impairments compared to subtractive regular-drilling technique, regardless of evaluation time or implant surface. (c) 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 615-623, 2019. (AU)

FAPESP's process: 12/19078-7 - Development and processing of Al2O3-ZrO2 translucent composite for CAD/CAM monolithic prostheses: the effect of aging on biaxial flexural strength
Grantee:Estevam Augusto Bonfante
Support Opportunities: Research Grants - Young Investigators Grants
FAPESP's process: 16/18818-8 - Multi-User Equipment approved in grant 2012/19078-7: ElectroPuls E3000 Linear-Torsion All-Electric dynamic test instrument package
Grantee:Estevam Augusto Bonfante
Support Opportunities: Multi-user Equipment Program