Advanced search
Start date
Betweenand
(Reference retrieved automatically from Web of Science through information on FAPESP grant and its corresponding number as mentioned in the publication by the authors.)

Green volumetric procedure for determining biodiesel content in diesel blends or mixtures with vegetable oils exploiting solubility differences in an ethanol:water medium

Full text
Author(s):
Soares, Samara [1] ; Rocha, Fabio R. P. [1]
Total Authors: 2
Affiliation:
[1] Univ Sao Paulo, Ctr Nucl Energy Agr, Av Centenario 303, BR-1341600 Piracicaba, SP - Brazil
Total Affiliations: 1
Document type: Journal article
Source: FUEL; v. 276, SEP 15 2020.
Web of Science Citations: 1
Abstract

A practical and environmentally friendly volumetric procedure, which requires only water and ethanol and generates low waste volumes, is proposed for determining the amount of biodiesel in diesel blends or mixtures with vegetable oils. These applications are relevant for the quality control of commercial fuels, to estimate transesterification reaction yields and to detect product adulteration. The proposed method is based on the differences in solubility of biodiesel and either diesel or vegetable oils in an aqueous-ethanol medium. From samples dissolved in ethanol, the volumes of the aqueous-ethanol solution required to achieve a cloudy suspension are taken as analytical signals and directly correlated to the biodiesel amount in the samples. For biodiesel:diesel samples, a linear response was obtained from 7.0 to 25.0% (v/v), whereas two linear ranges, 20.0-50.0% (v/v) and 50.0-80.0% (v/v), were established for biodiesel:vegetable oil samples, depending on the water content in the titrant. For biodiesel:diesel blends, the coefficient of variation (n = 10) and the detection limit (99.7% confidence level) were estimated at 6.8% and 2.5% (v/v), respectively, and the corresponding values for the biodiesel:vegetable oil mixtures were 5.8% and 7.0% (v/v). The procedure takes 5 min and generates 10 mL of waste per determination. Results agreed with those attained by a flow-based spectrophotometric reference procedure at the 95% confidence level, as evaluated by a paired t-test and the elliptical joint confidence region test. The proposed method is a fast, practical, cost-effective, and environmentally friendly alternative for routine analysis, including point-of-care determinations. (AU)

FAPESP's process: 18/07687-5 - Exploitation of novel calibration strategies, digital images and flow analysis for biodiesel quality control
Grantee:Samara Soares
Support Opportunities: Scholarships in Brazil - Doctorate