Advanced search
Start date
Betweenand
(Reference retrieved automatically from Web of Science through information on FAPESP grant and its corresponding number as mentioned in the publication by the authors.)

One-year follow up on post-placental IUD insertion: A randomized clinical trial

Full text
Author(s):
Marangoni, Jr., Marcos [1] ; Laporte, Montas [1] ; Surita, Fernanda [1] ; Kraft, Maria B. [1] ; Bahamondes, Luis [1] ; Juliato, Cassia R. T. [1]
Total Authors: 6
Affiliation:
[1] Univ Campinas UNICAMP, Sch Med, Dept Obstet & Gynecol, Rua Alexander Fleming 101, BR-13083881 Campinas, SP - Brazil
Total Affiliations: 1
Document type: Journal article
Source: ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA; v. 100, n. 4 MAR 2021.
Web of Science Citations: 1
Abstract

Introduction Our objectives were to compare the 1-year follow-up clinical performance of the TCu380A intrauterine device (TCu380A-IUD) and levonorgestrel (LNG) 52-mg intrauterine system (IUS) inserted at post-placental period. Material and methods We conducted an open-label, parallel-group, randomized clinical trial, 1:1 with pregnant women admitted for childbirth independently of the mode of birth. Our primary outcome was expulsion up to 1 year after device placement by type of IUD and mode of delivery. During the follow up (42, 90 and 365 days (+/- 7 days) after device placement), an ultrasound was performed to evaluate the device position. Kaplan-Meier with log-rank test was used to compare the survival curves of the TCu380A IUD and the LNG IUS. Couple-Years of Protection after insertion of both devices was calculated. Results One hundred and forty women were randomized to the TCu380A IUD (n = 70) or the LNG IUS (n = 70). By the end of the first year after device placement, 38 women experienced device expulsion (27.1%), most of them (33/38; 86.8%) within the first 42 days after delivery. The expulsions were significantly higher among users of TCu380A IUD (39.4%) than among users of the LNG IUS (22.2%; P = .039), and among those with vaginal delivery (43.8%) than among women with cesarean delivery (15%; P = .003). The 1-year cumulative continuation rate was 64.2%, significantly higher for LNG IUS (73.1%) than for TCu380A IUD (54.4%; P = .03), and among women with cesarean delivery (77.6%) than for vaginal delivery (52%; P = .00). The post-placental IUD insertion provided 356.4 Couple-Years of Protection. Conclusions Two-thirds of women who accepted a post-placental IUD placement still used the device 1 year after childbirth. However, expulsion was the most prevalent reason for discontinuation, mainly within 42 days after device placement. The expulsion rate was significantly higher among TCu380A IUD users and among women with vaginal delivery. (AU)

FAPESP's process: 15/20504-9 - Clinical findings among progestin-only contraceptives' users
Grantee:Luis Guillermo Bahamondes
Support Opportunities: Research Projects - Thematic Grants