Advanced search
Start date
Betweenand
(Reference retrieved automatically from Web of Science through information on FAPESP grant and its corresponding number as mentioned in the publication by the authors.)

Automated online coupling of robot-assisted single drop microextraction and liquid chromatography

Full text
Author(s):
Vargas Medina, Deyber Arley [1] ; Rodriguez Cabal, Luis Felipe [1] ; Titato, Guilherme Miola [1] ; Lancas, Fernando Mauro [1] ; Santos-Neto, Alvaro Jose [1]
Total Authors: 5
Affiliation:
[1] Univ Sao Paulo, Sao Carlos Inst Chem, BR-13566590 Sao Carlos, SP - Brazil
Total Affiliations: 1
Document type: Journal article
Source: Journal of Chromatography A; v. 1595, p. 66-72, JUN 21 2019.
Web of Science Citations: 5
Abstract

A high-throughput and innovative setup has been developed to automate the online integration of single drop microextraction (SDME), liquid chromatography (LC) and high-resolution mass spectrometry (QqToF). SDME and LC were online hyphenated for the first time. SDME was carried out by a lab-made cartesian robot actuating a 100 mu L syringe, equipped with a three-way solenoid microvalve that allowed the online transference of the enriched extract to the chromatographic system, through a six-port switching valve. The complete method, including the synchronized robot action, valves, and the analytical instruments, was controlled by an Arduino Mega board. The merits of the proposed setup were demonstrated by the triazines determination in coconut water samples. The most relevant extraction parameters, such as drop size, exposure time, stirring effect, salt addition and pH were systematically investigated. Under optimized conditions (60 mu L drop volume and 10 min extraction time), the LC-UV enrichment factors (EF) and the extraction recoveries (ER) ranged between 15.2-18.4 and 11.4-13.8%, respectively. Using the SDME-LC-MS setup, the linear range, detection limit (S/N = 3) and precision (RSD, n = 6 at 0.25 mu g L-1 level of concentration) were 0.25-25 mu g L-1, 0.10 mu g L-1 and 16.8% for simazine; 0.25-25 mu g L-1, 0.05 mu g L-1 and 14.7% for atrazine; and 0.25-25 mu g L-1, 0.05 mu g L-1 and 18.5% for propazine, respectively. Although none of the analytes were detected in the evaluated commercial samples, the results indicate that the proposed online SDME-LC setup is a competitive analytical strategy for the determination of target organic compounds in complex matrices. (C) 2019 Elsevier B.V. All rights reserved. (AU)

FAPESP's process: 17/02147-0 - Single drop chromatography and its coupling to mass spectrometry: instrumental strategies, development of materials, automation and analytical applications
Grantee:Fernando Mauro Lanças
Support Opportunities: Research Projects - Thematic Grants
FAPESP's process: 10/19910-9 - Development of green chemistry strategies on chromatography and application to the evaluation of antibiotics degradation in wastewaters by fixed-bed anaerobic bioreactors
Grantee:Alvaro José dos Santos Neto
Support Opportunities: Regular Research Grants
FAPESP's process: 16/21950-5 - Automation strategies for miniaturized sample preparation, case: automated online in syringe stirred SDME
Grantee:Deyber Arley Vargas Medina
Support Opportunities: Scholarships abroad - Research Internship - Doctorate